Search found 97 matches

by TonyP62
Mon Aug 08, 2016 8:45 pm
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

tonyp62 4.140kW Compare: Tips Date▼ Generated▼ Efficiency▼ Exported▼ Peak Power Peak Time Conditions 08/08/16 22.386kWh 5.407kWh/kW 22.386kWh 3.024kW 2:30PM Fine As you can see from this code, we can send to pvoutput.org site the exported value. I insert it manually every day. So i ask you if it's ...
by TonyP62
Mon Aug 08, 2016 8:01 pm
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

The test.php works fine , but it insert the Power and Energy Used into pvoutput.org (1 Watt).
I only need to insert the "Exported" value that must be the same as Production in pvoutput.org site.
There is a different solution ?
by TonyP62
Mon Aug 08, 2016 7:42 pm
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

oh that 'exported' seem to be calculated via the consumption not via the extended values. You may create a file config/pvoutput/consumption/test.php for a try <?php $CONSUMED_WHD = 1; $CONSUMED_W = 1; ?> I create this file and tested. But the "Exported" Value on pvoutput.org is not changed. Pleas h...
by TonyP62
Mon Aug 08, 2016 11:15 am
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

Oops sorry, i just review the code. 123s does indeed do the difference :oops: That should work if you use $pvo_v10=$KWHDtot; I put this code on my extended1.php file and restart 123solar service but i don't see any exported value on pvoutput.org as you can see here . This extended value will be sen...
by TonyP62
Mon Aug 08, 2016 10:27 am
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

Thanks for explanation, JeanMarc.
Now is more clear how 123solar works.
So, the only solution is to replace my smart meter and use it with MeterN.
by TonyP62
Mon Aug 08, 2016 10:15 am
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

I ask you, if it's possible to insert this into the extended1.php like this :

Code: Select all

$pvo_v9=null;
$pvo_v10=(round($array2[1], 1);
In this way, when 123solar send values to pvoutput.org, it send the same value for Production and Exported .
Do you think this is a probably solution ?
Thanks !
by TonyP62
Mon Aug 08, 2016 9:19 am
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

Hi JeanMarc.
I ask you this, because i don't have a smart meter now and all energy produced from my PV is actually exported.
In which way i can set the extended data file for sending exported value=production value to pvoutput ?
Thanks !
by TonyP62
Mon Aug 08, 2016 8:57 am
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

Very good job, JeanMarc. It works with SBFspot 3.3.1 perfectly. I have a question for you: Into the extended data file for pvoutput.org , it's possible to define an array for "exported energy" ? Actually, i must insert this value manually on the pvoutput.org site using the same value of production. ...
by TonyP62
Tue Apr 26, 2016 7:25 pm
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

Hello, 123solar 1.6.8.2 is out to correct an annoying bug with the previous release : - Bug: Error line 369 with a PHP version prior to 5.5 Others bugs : - Style : Switch back to default if the style dosen't exist. - Updater : Few php warnings Enhancements : - Production: Daily level jump to detail...
by TonyP62
Mon Apr 25, 2016 8:35 am
Forum: 123solar
Topic: 123solar 1.6.8
Replies: 88
Views: 29445

Re: 123solar 1.6.8

jeanmarc wrote:And from which 123s version you're coming from ?
1.6.8