123solar 1.8
Re: 123solar 1.8
must be
d /run/lock 0777 root root -
L /var/lock 0777 - - - ../run/lock
right?
d /run/lock 0777 root root -
L /var/lock 0777 - - - ../run/lock
right?
Re: 123solar 1.8
Should be
Save and reboot
/run is a tmpfs, it mean changing the permission won't survive a reboot (please read what i say)
Code: Select all
d /run/lock 0777 root root -
L /var/lock - - - - ../run/lock
/run is a tmpfs, it mean changing the permission won't survive a reboot (please read what i say)
Re: 123solar 1.8
please add in help both stringsPlease read the help (yawn)
777 permissions in /var/lock and /run/lock
Re: 123solar 1.8
No because i don't know if this trick is available on every distros and the formatting may vary. Hence why if put a e.g.
d is directory
L is a link (no need to set perms there)
/run is a tmpfs (no need to change perms there)
123s is simple as i can, Linux is not, people should invest a bit of themself
d is directory
L is a link (no need to set perms there)
/run is a tmpfs (no need to change perms there)
123s is simple as i can, Linux is not, people should invest a bit of themself

Re: 123solar 1.8
terribly right!invest a bit of themself
please help me find this eroor in nginx log
(wrong array index)
20min after reboot - nginx error log > 90MB!
Code: Select all
Undefined offset: 3 in /srv/http/123solar/programs/programday.php on line 159" while reading response header from upstream,
Re: 123solar 1.8
Really, it fill with that error ? programday.php is call on minute
Did you have 3 inverters ?

Did you have 3 inverters ?
Re: 123solar 1.8
on my first Rpi i have 4 inverters
2working
2 suspended

total in one place i serve 9 inverters on 2rpi )))
2working
2 suspended

total in one place i serve 9 inverters on 2rpi )))
Re: 123solar 1.8
in this year max energy - 856kWh/day
Re: 123solar 1.8
i'll send you in PM my email with details
Re: 123solar 1.8
Hello,
Another small 123s release 1.8.4.2 :
Bug : Grid voltage Below threshold
New : One ileak/Riso message and log if the threshold are back ok
Clean-up :
Telegram add inverter names in message
Allow group chat (negative chat id)
Rewrited programlastdays was bugging if wrong energy files
..
Bye
Another small 123s release 1.8.4.2 :
Bug : Grid voltage Below threshold
New : One ileak/Riso message and log if the threshold are back ok
Clean-up :
Telegram add inverter names in message
Allow group chat (negative chat id)
Rewrited programlastdays was bugging if wrong energy files
..
Bye